Hi Guido,
I found your post from February regarding this issue and I now understand
what you are saying.
As I will be connecting to a pre-existing AD that was not setup by me, could
you tell me where I could find in Windows 2000 server that will tell me if
the AD is configured for "Pre Windows 2000 compatibility"??
If the server has not been configured for pre-compatibility, am I able to
change a setting somewhere so that it will be?
Thanks for your help
Jay
-----Original Message-----
From: Serassio Guido [mailto:guido.serassio@acmeconsulting.it]
Sent: Thursday, 17 July 2003 5:11 PM
To: jturner@bsis.com.au; Henrik Nordstrom
Cc: squid-users@squid-cache.org
Subject: RE: [squid-users] winbind and samba
Hi,
At 09.37 17/07/2003, Jay Turner wrote:
>And isn't this compatibility known as "mixed-mode"??
No, If your squid works fine in mixed-mode, it works on native mode too.
What is needed for running Squid + NTLM + Winbind + Samba + AD is the "Pre
Windows 2000 compatibility" configured during the installation of AD
(DCPromo of the FIRST DC in the domain). As say Henrik, see previous posts
for more details.
Regards
Guido
>-----Original Message-----
>From: Henrik Nordstrom [mailto:hno@squid-cache.org]
>Sent: Thursday, 17 July 2003 2:55 PM
>To: jturner@bsis.com.au; Tony Grace; 'squid'
>Subject: Re: [squid-users] winbind and samba
>
>
>On Thursday 17 July 2003 07.07, Jay Turner wrote:
>
> > I have had it working no worries against 2000 server's in
> > mixed-mode, but have read conflicting reports about NTLM in native
> > mode.
>
>If wbinfo -a says challenge/response works then it is fine.
>
>This requires compability with NT4 to be enabled in the directory.
>
>Regards
>Henrik
>
>--
>Donations welcome if you consider my Free Squid support helpful.
>https://www.paypal.com/xclick/business=hno%40squid-cache.org
>
>If you need commercial Squid support or cost effective Squid or
>firewall appliances please refer to MARA Systems AB, Sweden
>http://www.marasystems.com/, info@marasystems.com
-
========================================================
Guido Serassio
Acme Consulting S.r.l.
Via Gorizia, 69 10136 - Torino - ITALY
Tel. : +39.011.3249426 Fax. : +39.011.3293665
Email: guido.serassio@acmeconsulting.it
WWW: http://www.acmeconsulting.it/
Received on Thu Jul 17 2003 - 03:19:11 MDT